pH Neutralization wastewater treatment with ClearFox® mobile container system
Ask us any question
Technical Information
Project
Data
2019
Location
Saudi Arabia
Application
ClearFox® Container neutralization Plant
Size
161 m³/d (6,7 m³/h
Effluent quality
Direct discharge
Modules
pH neutralization unit
Characteristics
1. Main inflow: pH 0-1 (inorganic acids), or pH 3-5 (organic acids and partially pre-diluted inorganic acids)
2. Inflow of bases: pH 13-14
3. Water inflow (dilution)
Drain: pH 6-9
Features
Acidic and partly basic liquids from oil rigs, pH neutralization in a single container
Situation
The extraction of crude oil, as well as its processing and transport is essential to maintain the economy.
Our client is one of the largest waste management companies in the region, acting as a service provider for a company that produces crude oil. During drilling operations, a wide variety of liquids are produced that need to be treated and neutralized.
Problem
During oil production on a drilling platform, liquid waste is produced in the form of strong acids and sometimes also as strong alkalis. In order for these liquids to be handled, an intermediate step must be carried out to bring all inflows to a comparably neutral pH level.
The plant doing this has to be easy to use, installed in a single ClearFox® container and capable of carrying out the neutralization process continuously.
Solution
Both inflows lead into a buffer, which serves as a buffer and at the same time gives the customer the possibility to carry out a certain pre-neutralization by a charging management.
A mixing tank in the form of a batch treatment process, which is mixed using the mammoth pump principle, ensures that the liquid waste is treated. First, two dosing pumps dose chemicals for pH neutralisation. Water is fed into the tank during the mixing process as a support. This makes all moving parts outside the buffer and mixing tank in the ClearFox® container comparatively easy to maintain. The process of ph Neutralization is rounded off by two control units that regulate this process.
Technical Data
- pH Neutralization unit
- Capacity: 161 m³/d (6.7 m³/h)
- Input: liquids with pH 0-14, mostly acids